Summer check

Is it broken, or is it just 106 outside?

On the hottest afternoons a healthy system can sit a few degrees above the set point. Knowing which side of that line you are on is worth a phone call either way.

The check

Three numbers and one question. It runs in your browser and nothing is sent anywhere. It is a guide to whether the gap you are seeing is normal for the weather — it cannot tell you what has failed.

Use the thermostat's own reading for the indoor temperature if you have nothing else.

Is the outdoor unit running?

What this looks like

Why the gap happens

Four things that decide a hot afternoon

  • Design temperatureEquipment is sized to hold a comfortable indoor temperature at a chosen outdoor design figure. Above that, everything runs continuously and still drifts. That is arithmetic, not a defect.
  • Coil conditionA condenser coil packed with dust cannot reject heat. It is the single most common reason a system that was fine in June struggles in late July.
  • Duct lossesDucts in a very hot attic lose cooling on the way to the room, and a leaking return pulls attic air into the system. Both look exactly like an undersized system.
  • Sun and glassWest-facing glass on a 105°F afternoon adds load faster than most systems can remove it. Shading it is cheaper than upsizing anything.